Full Publication List

  1. GC-MS with Cold-EI Demonstration Video
  2. Classical EI-SMB Ion Source and its Comparison with Classical EI with High Efficiency Source
  3. Achieving the Lowest Limits of Identification – GC-MS with Cold EI versus Standard EI with High Efficiency Source
  4. Permethrin Drug Impurity Analysis with GC-MS with Cold EI and the Road to Failure in Such Analysis by GC-MS with Standard EI
  5. Cold EI Versus Low Electron Energy EI
  6. Lipids in Human Serum Analysis by the 5975-SMB GC-MS with Cold EI
  7. Impurities Analysis in Active Pharmaceutical Ingredients Comparison of Cold EI with Standard EI
  8. Triglycerides in Oils Analysis by the 5975-SMB GC-MS with Cold EI
  9. How Enhanced Molecular Ions in Cold EI Improves Sample Identification by the NIST Library
  10. Soft Cold EI – Approaching Molecular Ion Only with Electron Ionization
  11. Open Probe Fast GC-MS - Real Time Analysis with Separation
  12. Linearity, Sensitivity and Response Uniformity Comparison of the Aviv Analytical 5975-SMB with Cold EI and the Agilent 5977A GC-MS with Standard EI
  13. Explosives Analysis with the 5975-SMB GC-MS with Cold EI
  14. Deuterium Exchange Analysis for Improved Structural Elucidation with the 5975-SMB GC-MS with Cold EI
  15. Pesticide Analysis by Pulsed Flow Modulation GCxGC-MS with Cold EI – An Alternative to GC-MS-MS
  16. Pulsed Flow Modulation GCxGC-MS with Cold EI – The Emergence of Novel Concept of GCxGCxMS
  17. Extending the Range of Compounds Amenable for GC-MS Analysis
  18. Organo-Iodine Compounds Analysis by the 5975-SMB GC-MS with Cold EI
  19. What Can be Improved in GC-MS – When Multi Benefits are Transformed into a GC-MS Revolution
  20. Free Fatty Acids Analysis by GC-MS - Cold EI Versus Standard EI
  21. Nitrogen as an Alternative for Helium as a Carrier Gas for 5975-SMB GC-MS with Cold EI
  22. Does this Pill Contain its Claimed Active Ingredients? Finasteride in Male Baldness Treatment Pills
  23. How Does MS-MS Fail
  24. Isomer Distribution Analysis – A New Tool for Organic Geochemistry Analysis
  25. Peak Tailing – Like an Iceberg, it Hides Signal More than Commonly Perceived
  26. Enhancing the Identification Capabilities of EI GC-MS - How Quadrupole GC-MS can compete with High Resolution TOF
  27. Advanced GC-MS Presentations of Aviv Analytical in Pittcon 2013
  28. Extraterrestrial Allende Meteorite Analysis by the Aviv Analytical ChromatoProbe and 5975-SMB GC-MS with Cold EI
  29. The Discovery of New Ant Head Compounds via ChromatoProbe Sampling and 5975-SMB GC-MS with Cold EI
  30. C-4 Explosives Characterization by the 5975-SMB GC-MS with Cold EI
  31. Drug Impurities Analysis by the Aviv Analytical 5975-SMB GC-MS with Cold EI
  32. A Universal Method for Pesticide Analysis with the 5975-SMB GC-MS with Cold EI
  33. Selectivity Enhancement for the Reduction of Matrix Interference in GC-MS – Cold EI as an Alternative to MS-MS
  34. Organic Chemical Reaction Yields Optimization by GC-MS with Cold EI and Walk-by GC-FID
  35. Measurement and Optimization of Organic Chemical Reaction Yields by GC-MS with Cold EI
  36. Ants Communication Exploration via their Wax Analysis by GC-MS with Cold EI – The Unique Role of Hydrocarbon Isomer Distributions
  37. Flies Wax Analysis by GC-MS with Cold EI and its Comparison with Standard EI
  38. Cold EI – Approaching the Ideal GC-MS Ion Source
  39. Pistol Oil Analysis by the Aviv Analytical 5975-SMB GC-MS with Cold EI – A New Forensic Method for the Verification of Pistol Holding
  40. Approaching a Step Forward Towards the CSI Vision - Cannabis Seeds Identification with the 5975-SMB GC-MS and Cold EI
  41. Arson Analysis by GC-MS with Cold EI – Fuel Fingerprinting by Isomer Distribution Analysis
  42. Nonoxynol-9 Spermicide Analysis using the Aviv Analytical 5975-SMB GC-MS with Cold EI
  43. Glycidyl Esters Analysis by the Aviv Analytical 5975-SMB GC-MS with Cold EI
  44. Jojoba Oil Analysis using the Aviv Analytical 5975-SMB GC-MS with Cold EI
  45. Beeswax in Fruit and Vegetables Analysis and the Emerging Challenge of Material Identification
  46. Helium Shortage and Hydrogen as a Carrier Gas for GC-MS
  47. AM2201 Synthetic Cannabis Analysis using the 5975-SMB GC-MS with Cold EI
  48. Hydrocarbon Isomers - Why Aren't They Analyzed
  49. Tetryl Analysis using the 5975-SMB GC-MS with Cold EI
  50. The Effects of Enhanced Molecular Ions on NIST's Identification Probability
  51. By how much is the Molecular Ion Enhanced in Cold EI
  52. Dramatically Improved Hydrocarbon Analysis with the 5975-SMB GC-MS with Cold EI
  53. Very Fast Heroin Analysis – The Role of Flow Programming
  54. Sample Identification – Which is a Better Method and Instrument, GC-MS with its Library Search or LC-HR-MS with the Provision of Elemental Formula?
  55. Signal versus Signal to Noise Ratio in Mass Spectrometry